ERROR ANALYSIS AND CORRECTION SCHEME IN C-ADS INJECTOR-I*

cai meng,jingyu tang,zhihui li
2012-01-01
Abstract:C-ADS Injector-I is a 10-mA 10-MeV CW proton linac. It uses a 3.2-MeV normal conducting 4-Vane RFQ and 12 superconducting single-spoke cavities. According to the detailed sensitivity analysis of alignment and RF errors, the error tolerance of both static and dynamic ones for Injector-I is presented. The simulation results show that with the errors there are beam losses, the residual orbit is too large, which will produce significant emittance growth, so that the correction is necessary for Injector-I. After detailed numerical studies, a correction scheme and monitor distributions are proposed. After correction the rms residual orbit can be controlled within 0.4 mm and RMS emittance growth can be controlled within 10%, but it still has 1.7×10 beam loss, which comes from the RF errors and small longitudinal acceptance. To minimize beam loss, the causes of beam loss have been studied and a short period Injector-I lattice with larger longitudinal acceptance have been designed with good error tolerance performance. According to detailed analysis and simulations, as a consequence, longitudinal emittance control and longitudinal distribution control as well as large longitudinal acceptance are the key to minimize beam losses and emittance growth in low energy section.