Study of influence of temperature decreasing in stages to nutrient removal in A2/O process

Yu JIN,Jian-zheng LI,Nan-qi REN,Jun-guo HE
DOI: https://doi.org/10.3969/j.issn.1672-0946.2014.04.008
2014-01-01
Abstract:The seasonal change of temperature in north China has significant impact on the performance of urban sewage treatment process , especially low temperature in winter make the effluent difficult to meet the Chinese national discharge standards ( GB18918-2002 ) . Thus , it is important to understand the performance of sewage treatment system following sea -sonal temperature variations .Based on the operation of a lab -scale A2/O sewage treatment process , the performance characteristics following the temperature drop from 23℃to 18℃, 14 ℃and 11 ℃, step by step were investigated .The HRT for the A2/O process was 10 h, with an average influent COD , NH3-N, TN and TP of 275, 46, 50 and 5.3 mg/L, respec-tively.The results showed that the average effluent COD and TP could meet the First Grade A of the Chinese national discharge standards ( GB8918-2002 ) , even though their con-centration raised from 28 and 0.2 mg/L to 40 and 0.3 mg/L, respectively, when the tem-perature dropped from 23℃to 11℃.On the contrary , the residual NH 3-N and TN in the effluent was up to 7.58 and 16.58 mg/L at 11℃, respectively, unable to meet the First Grade A.The results suggested that the regulations and control measures to ensure the efflu-ent quality should focus on the enhancement of nitrification and denitrification in the A 2/O process .
What problem does this paper attempt to address?