The running performances of combined process of CEPT-MBBR in different temperatures

Zhang Yan,Zhou Xiao-hong,Chen Hong-bin,He Qun-biao,Qu Ji-ning
DOI: https://doi.org/10.3969/j.issn.1002-8471.2006.z1.009
2006-01-01
Abstract:Pilot experiments were accomplished in several months at low temperature(7-15℃),increasing temperature(14-22℃)and high temperature(27-32℃). The results showed that the temperature had a weak influence on the removal efficiencies of CODCr,SS and TP, however, biological nitrification and denitrification would be weaken at low temperature with the running parameters of HRT of MBBR 3. 3-6 h, dosage of PAC with 30 mg/L and filling ratio of moving carriers with 30%. When the temperature increased, the treatment effect of NH3-N and TN would be better. When the temperature went up to 20℃, the effluent concentration of NH3-N could be less than 1 mg/L and removal rate of TN was about 50%; In deep winter ,such as at the temperature of 7-13℃, the removing rate of TN in the Moving Bed Biofilm Reactor was only 18. 4% and the average concentration of effluent NH3 - N was 7. 84 mg/L. Even if in winter, the effluents could meet GB 18918-2002.
What problem does this paper attempt to address?