Analysis Of Bf Hearth Reasonable Cooling System Based On The Water Dynamic Characteristics

haibin zuo,kexin jiao,jianliang zhang,qian li,cui wang
DOI: https://doi.org/10.1007/978-3-319-48217-0_51
2015-01-01
Abstract:A rational cooling water system is the assurance for long campaign life of blast furnace. In the paper, the heat transfer of different furnace period and different furnace condition based on the water quality characteristics were analysed, and the reason of the heat flux over the normal from the hydrodynamics was analysed. The results showed that, the vapour-film and scale existence significantly influenced the hearth heat transfer, which accelerated the brick lining erosion. The water dynamic characteristics of the parallel inner pipe or among the pipes were the main reason for the abnormal heat flux and film boiling. As to the reasonable cooling water flow, the gas film and the scale should be controlled and the energy saving should be considered.