A Near-Infrared Acetylene Detection System Based on a 1.534 Μm Tunable Diode Laser and a Miniature Gas Chamber

Qixin He,Chuantao Zheng,Huifang Liu,Bin Li,Yiding Wang,Frank K. Tittel
DOI: https://doi.org/10.1016/j.infrared.2016.01.006
IF: 2.997
2016-01-01
Infrared Physics & Technology
Abstract:A near-infrared (NIR) dual-channel differential acetylene (C2H2) detection system was experimentally demonstrated based on tunable diode laser absorption spectroscopy (TDLAS) technique and wavelength modulation spectroscopy (WMS) technique. A distributed feedback (DFB) laser modulated by a self-developed driver around 1.534μm is used as light source. A miniature gas chamber with 15cm path length is adopted as absorption pool, and an orthogonal lock-in amplifier is developed to extract the second harmonic (2f) signal. Sufficient standard C2H2 samples with different concentrations were prepared, and detailed measurements were carried out to study the detection performance. A good linear relationship is observed between the amplitude of the 2f signal and C2H2 concentration within the range of 200–10,000ppm, and the relative measurement error is less than 5% within the whole range. A long-term monitoring lasting for 20h on a 1000ppm C2H2 sample was carried out, and the maximum concentration fluctuation is less than 2%. Due to the capability of using long-distance and low-loss optical fiber, the gas-cell can be placed in the filed for remote monitoring, which enables the system to have good prospects in industrial field.
What problem does this paper attempt to address?