A systematic comparison of solvents and their concentrations in bitumen gravity drainage under controlled thermodynamic conditions
Hassan Amer,Kai Sheng,Ryosuke Okuno,Abdullah Al-Gawfi,Petro Nakutnyy
DOI: https://doi.org/10.1016/j.fuel.2023.129723
IF: 7.4
2024-02-01
Fuel
Abstract:Solvent-assisted SAGD (SA-SAGD) has been studied as an alternative to improve the efficiency of SAGD. This paper reports a new set of experimental data for SA-SAGD and analyzes the characteristics of bitumen-solvent mixing in the experiments using history-matched numerical models. The dimensions of the sand pack were 3 in. in diameter and 15 in. in length, and the sand pack was contained in a 25-L cylindrical pressure vessel. An annular void space surrounded the sand pack with a gap thickness of 1 in., within which a steady state flow of the injected vapor phase maintained the controlled pressure, temperature, and composition. Therefore, the gravity drainage in the sand pack occurred at a set of specified thermodynamic conditions for the surrounding annular steam chamber, unlike transient conditions near the edge of a steam chamber in larger-scale steam injection processes. In addition to SAGD as the base case, five sets of SA-SAGD were performed: 20 mol% C4, 40 mol% C4, 10 mol% C8, 20 mol% C8, and 10 mol% condensate coinjected with steam at 3500 kPa. The peak oil production rate was 9.84 cm3/min with SAGD, 14.61 cm3/min with 20 mol% C4-SAGD, 16.34 cm3/min with 40 mol% C4-SAGD, 31.33 cm3/min with 10 mol% C8-SAGD, 12.36 cm3/min with 20 mol% C8-SAGD, and 12.33 cm3/min with 10 mol% condensate-SAGD. SAGD was the least effective in bitumen gravity drainage, while the 10 mol% C8-SAGD was the most effective. Increasing the C4 molar concentration from 20 to 40 mol% slightly increased the peak rate; however, the peak rate in C8-SAGD significantly was decreased by increasing the C8 concentration from 10 to 20 mol%. This counter-intuitive result was reported in a few simulation studies with heavy solvents (e.g., C7 and C12) in the literature, but had not been experimentally confirmed before this research. Although the condensate contained 93 mol% C7-like pseudo component (C7, eq), the peak rate of 10 mol% condensate-SAGD was much smaller than that of 10 mol% C8-SAGD. These experimental observations highlight the practical importance of understanding the sensitivity of bitumen gravity drainage to heavy-solvent concentrations near the edge of a steam chamber in SA-SAGD.
energy & fuels,engineering, chemical