Experimental Study on Paschen Discharge in Helium for High Voltage Cryogenic Insulation Material

Zheng Jinxing,Song Yuntao,Chunlong Zhou,Huang Xiongyi,Lu Kun,Wang Jun,Ding Kaizhong,Zhu Haisheng
DOI: https://doi.org/10.1007/s10894-014-9717-2
IF: 1.793
2014-01-01
Journal of Fusion Energy
Abstract:According to the requirements of large superconducting components, all the solid superconducting insulation of current leads, magnets, cooling and measurement pipeline at high potential should withstand 80–300 K thermal cycles. If helium leak or pipe leak taken place, and insulation has been formed some flaws, Paschen discharge would be occur. The experimental program aimed at analyzing the low-temperature electro-physical performance of solid superconducting insulation, which was designed with different configuration such as thickness, material structure and so on. The dielectric performance of both pre-preg cryogenic insulation and the wet wrap cryogenic insulation were studied. Both of the dielectric strength of the two type insulation is in the range from 11 to 23 kV/mm at 80 K helium condition. Besides, both of the two type insulation samples of 3 and 5 mm thickness can withstand 30 kV under various helium pressures at 80 K.
What problem does this paper attempt to address?