Experimental investigation on a pulsating heat pipe with low number of turns at liquid hydrogen temperature range

Cong Liu,Xiao Sun,Dongyang Han,Chunjie Yan,Zhihua Gan
DOI: https://doi.org/10.16711/j.1001-7100.2018.06.005
2018-01-01
Abstract:In order to cool Mg B2 superconducting material, the pulsating heat pipe (PHP) around liquid hydrogen temperature at Institute of Refrigeration and Cryogenics, Zhejiang University was studied by experiment. When filling ratio is 55. 8%, heating power is 0. 1 W, PHP with low number of turns is starting. With the increasing of the heating power, PHP experiences 3 periods: start-up, pulsation, and dry out. The results show that during the start-up, the fluctuation of PHP's temperature difference is large, and the heat transfer performance of PHP is poor. But during pulsation period, the fluctuation of PHP's temperature difference is very small, and the heat transfer performance of PHP is good. When filling ratio is 27. 8%, the PHP achieves the highest effective thermal conductivity of 68 k W/ (m·K) at the heating power of 0. 6 W. At this moment, the temperature difference between the condenser and the evaporator is 0. 29 K.
What problem does this paper attempt to address?