Handling Radiation Generated During an Ion Source Commissioning

H. T. Ren,J. Zhao,S. X. Peng,P. N. Lu,Q. F. Zhou,Y. Xu,J. Chen,T. Zhang,A. L. Zhang,Z. Y. Guo,J. E. Chen
DOI: https://doi.org/10.1063/1.4833925
2013-01-01
Abstract:Radiation is an important issue, which should be carefully treated during the design and commissioning of an ion source. Measurements show that X-rays are generated around the ceramics column of an extraction system when the source is powered up to 30 kV. The X-ray dose increases greatly when a beam is extracted. Inserting the ceramic column into a metal vacuum box is a good way to block X-ray emission for those cases. Moreover, this makes the online test of an intense H+ ion beam with energy up to 100 keV possible. However, for deuteron ion source commissioning, neutron and gamma-ray radiation become a serious topic. In this paper, we will describe the design of the extraction system and the radiation doses of neutrons and gamma-rays measured at different D+ beam energy during our 2.45 GHz deuteron electron cyclotron resonance ion source commissioning for PKUNIFTY (PeKing University Neutron Imaging FaciliTY) project at Peking University.
What problem does this paper attempt to address?