Neutronic design and simulated performance of Peking University Neutron Imaging Facility (PKUNIFTY)

Weiwei Wen,Hang Li,Yubin Zou,Guoyo Tang,Dawei Mo,Yuanrong Lu,Zuiyu Guo
DOI: https://doi.org/10.1016/j.nima.2010.12.194
2011-01-01
Abstract:The Peking University Neutron Imaging Facility (PKUNIFTY) is a Radio Frequency Quadruple (RFQ) accelerator based system. The fast neutrons are produced by 2MeV deuterons bombarding beryllium target. The moderator, reflector, shielding and collimator have been optimized with Monte–Carlo simulation to improve the neutron beam quality. The neutrons are thermalized in water cylinder of Φ26×26cm2 with a polyethylene disk in front of Be target. The size of deuteron beam spot is optimized considering both the thermal neutron distribution and the demand of target cooling. The shielding is a combination of 8cm thick lead and 42cm thick boron doped polyethylene. The thermal neutrons are extracted through a rectangular inner collimator and a divergent outer collimator. The thermal neutron beam axis is perpendicular to the D+ beam line in order to reduce the fast neutron and the γ ray components in the imaging beam. When the neutron yield is 3×1012n/s and the L/D is 50, the thermal neutron flux is 5×105n/cm2/s at the imaging plane, the Cd ratio is 1.63 and the n/γ ratio is 1.6×1010n/cm2/Sv.
What problem does this paper attempt to address?