Radio-Frequency Power Test of A Four-Rod Rfq Accelerator for Pkunifty

Zeng Hong-Jin,Liu Ge,Lu Yuan-Rong,Chen Wei,Zhou Quan-Feng,Zhu Kun,Xia Wen-Long,Shi Ben-Liang,Gao Shu-Li,Yan Xue-Qing,Guo Zhi-Yu,Chen Jia-Er
DOI: https://doi.org/10.1088/0256-307x/29/6/062901
2012-01-01
Chinese Physics Letters
Abstract:A four-rod radio frequency quadruple (RFQ) accelerator is designed, manufactured, installed and commissioned for the Peking University Neutron Imaging Facility (PKUNIFTY). This 2699.6-mm-long RFQ accelerator with the mean aperture radius of 3.88 mm is operating at 201.5 MHz in pulse mode. An inter-electrode voltage of 70 kV is needed to accelerate the injected 50 keV 40 mA D+ ions up to 2 MeV. We present the rf system, high rf power feeder design, lower rf measurements and higher rf power test. Especially, the rf commissioning was carried out with rf power up to similar to 280 kW and duty factor of 4%. The measured x-ray spectrum shows that the rf inter-electrode voltage reaches 70.7 kV. It is found that the specific shunt impedance of the RFQ cavity reaches 52.7 k Omega.m.
What problem does this paper attempt to address?