Detection of fatigue-induced micro-cracks in a pipe by using time-reversed nonlinear guided waves: a three-dimensional model study.

Xiasheng Guo,Dong Zhang,Jie Zhang
DOI: https://doi.org/10.1016/j.ultras.2012.02.014
IF: 4.2
2012-01-01
Ultrasonics
Abstract:Localization of fatigue-related micro-cracks in pipelines is of increasing importance in industrial applications. A three-dimensional (3D) fatigue-crack imaging technique combining nonlinear guided waves with time reversal is proposed in this paper for potential applications in pipeline inspections. By using this method, the non-classical nonlinear guided waves generated from micro-cracks with hysteretic behavior are recorded, and the third harmonic waves are used to reconstruct the fatigue-crack images in a pipe by using a time reversal (TR) process. The feasibility of this method is examined by the imaging simulations for a steel pipe with varied defect areas. A finite-difference time-domain (FDTD) code is programmed to solve the wave equations under cylindrical coordinates, and simulate the experimental process of wave propagation. The results show that: (1) the proposed technique has excellent spatial retrofocusing capability; (2) the accuracy of defect localization and sizing depends on the crack orientation and the adopted guided wave mode; and (3) different displacement/stress components have varied sensitivities to the crack orientation. (C) 2012 Elsevier B.V. All rights reserved.
What problem does this paper attempt to address?