High-Temperature Sensor Based on Fabry-Perot Interferometer in Microfiber Tip
Zhenshi Chen,Songsong Xiong,Shecheng Gao,Hui Zhang,Lei Wan,Xincheng Huang,Bingsen Huang,Yuanhua Feng,Weiping Liu,Zhaohui Li
DOI: https://doi.org/10.3390/s18010202
IF: 3.9
2018-01-12
Sensors
Abstract:A miniaturized tip Fabry-Perot interferometer (tip-FPI) is proposed for high-temperature sensing. It is simply fabricated for the first time by splicing a short length of microfiber (MF) to the cleaved end of a standard single mode fiber (SMF) with precise control of the relative cross section position. Such a MF acts as a Fabry-Perot (FP) cavity and serves as a tip sensor. A change in temperature modifies the length and refractive index of the FP cavity, and then a corresponding change in the reflected interference spectrum can be observed. High temperatures of up to 1000 °C are measured in the experiments, and a high sensitivity of 13.6 pm/°C is achieved. This compact sensor, with tip diameter and length both of tens of microns, is suitable for localized detection, especially in harsh environments.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation