Analysis and Enhancing of Self-Breakdown Voltages of A Multistage Gas Switch

Peitian Cong,Tieping Sun,Aici Qiu,Zhengzhong Zeng
DOI: https://doi.org/10.1109/tps.2012.2227125
IF: 1.368
2013-01-01
IEEE Transactions on Plasma Science
Abstract:A six-stage gas switch developed for linear transformer drivers is presented in this paper. The switch features an easy-handling structure consisting of stackable cylindrical insulators and brimmed toroidal electrodes. Following an electrode conditioning procedure, the switch and one of its gaps undergo self-breakdown tests by which normal distribution parameters of the self-breakdown voltage at each experimental air pressure are determined. Assuming that all gaps are the same, the switch's voltage with a 50% self-breakdown probability is predicted as the summed voltage of six gaps which individually have a 10.9% self-breakdown probability of voltage being calculated by using the experimentally determined normal function. The calculated result is 7-14 kV higher than the measured voltage because of a nonuniform voltage distribution which is later confirmed by using unequal gaps. For a more uniform voltage distribution, electrodes are revised to suppress corona discharge, and this revision has finally increased the switch hold-off voltage by 4-6 kV, which is the same as a resistive divider.
What problem does this paper attempt to address?