Research on Unbalanced-Load Correction Capability of Two Power Electronic Transformer Topologies

Xinyu Wang,Jinjun Liu,Shaodi Ouyang,Fei Meng
DOI: https://doi.org/10.1109/TPEL.2014.2331701
2015-01-01
Abstract:Compared with conventional power transformer, power electronic transformer (PET) has many merits and an increasing possibility to replace it in the future. In this paper, the unbalanced-load correction capability of two H-bridge based three-phase three-stage modular PET topologies, the separate-phase-connection (SPC) one and the cross-phase-connection (CPC) one, are analyzed and compared. Both of the SPC and CPC consist of three stages: a modular multilevel ac-dc input stage, an isolation stage with several independent modular dual active bridge (DAB) dc-dc converters, and a dc-ac output stage with single-phase-inverter parallel-connected structure. Based on the control strategy, it is found that the SPC is suitable for dealing with full-range unbalanced load under the condition of increasing the input-stage current stress. For the SPC feeding, one load or three loads with identical power polarity, the current stress shall be theoretically increased up to 115% of the rated one, while the percentage is 153% when the SPC feeds three loads with different power polarity. On the contrary, the CPC is only suitable for dealing with partial unbalanced-load conditions. Extendedly, the third so-called full-range-power auto-balance PET is proposed to deal with unbalanced load, the performance of which is verified by simulation results. A downscaled prototype for SPC and CPC is built and tested. Experimental results verify the unbalanced-load correction performance of SPC and CPC.
What problem does this paper attempt to address?