Comparison of Desimetric Parameters Between IMRT and 3D-CRT for Postoperative Irradiation in Locally Advanced Gastric Carcinoma

DENG Qing-hua,LI Pu,YAN Feng-qin,LIU Peng,LU Ke,TANG Zhong-zhu,MA Sheng-lin,ZHU Yuan
DOI: https://doi.org/10.16073/j.cnki.cjcpt.2011.09.022
2011-01-01
Abstract:OBJECTIVE: To compare the radiotherapy plan between intensity modulated radiation therapy(IMRT) and 3-dimensional conformal radiation therapy(3D-CRT),and evaluate the dose distribution in target volume and organs at risk.METHODS:Twenty-nine patients with locally advanced gastric carcinoma were included in this study.For each patient IMRT plan and 3D-CRT plan were generated.The dose reference point was at isocenter and prescribed to 45 Gy.Dose volume histogram(DVH) and dose distribution curves were used to evaluation the plans according to the prescribed dose and dose constraints for organs at risk,including liver,left kidney,right kidney and spinal cord.RESULTS: When compared with conventional 3D-CRT,IMRT had better target dosimetric distribution(P0.001),higher mean dose(P0.001) and better conformality(P0.05).IMRT significantly reduced the mean dose of V5 and V20 to the liver(P0.001 and P0.05 respectively) and V12 and V22.5 of left kidney(P0.001),while the reduction in the dose to the right kidney(V12 and V22.5) and spinal cord was not significant.CONCLUSION: Compared to 3D-CRT,IMRT has certain advantages in target dosimetric distribution and protection to targets at risk including liver and left kidney.
What problem does this paper attempt to address?