Dosimetric Comparison Between Conventional and Three Dimensional Conformal Radiation Therapy for Esophageal Carcinoma

陈文娟,潘建基,王捷忠,柏朋刚
DOI: https://doi.org/10.3969/j.issn.1001-5930.2007.06.027
2007-01-01
Abstract:Objective To compare the dose distribution in the planning target volume (PTV) and organs at risk of conventional and 3-dimentional radiotherapy (3DCRT) in treating esophageal carcinoma.Methods 3 field conventional radiotherapy and 3DCRT treatment planning were performed in the 3-D treatment planning system for 28 patients with esophageal carcinoma.Dose volume histogram (DVH) was used to compare the dose distribution in the PTV,lungs and heart of the two techniques.Normal tissue complication possibility (NTCP) was used to evaluate the possibilities of radiation induced pneumonitis.Results There was no significant difference of the two techniques in terms of the dose coverage of PTV.The volume of heart receiving at least 40 Gy (V40) and 50 Gy (V50),and the volume of both lungs receiving at least 20 Gy (V20) and 30 Gy (V30) were significantly different by the two techniques.Conclusion Compared to the conventional radiotherapy technique,3DCRT could reduce the dose to the heart and lungs,and decrease the radiation induced pneumonitis possibilities.
What problem does this paper attempt to address?