Dynamic Characteristics Measurement of Silicon Micro-Cantilever in Low Temperature Environment

D. S. She,X. D. Wang,X. W. Zhang,L. D. Wang
DOI: https://doi.org/10.4028/www.scientific.net/kem.483.18
2011-01-01
Key Engineering Materials
Abstract:The dynamic testing system for MEMS in low temperature environment has been developed. A thermoelectric cooling refrigerator was utilized to generate the low temperature environment. The base excitation device was established using the piezoelectric ceramic as the driving source. A vacuum chamber was designed to protect the micro-structure from the humid air. Through the base impact excitation, the resonance frequencies are obtained by analyzing the impulse response signals. The frequency response of micro-cantilever was obtained by using both BIST method and laser Doppler vibrometer. The dynamic testing experiments for the silicon micro-cantilever were carried out from -50°C to room temperature. The result shows that the resonance frequency slightly increases with the decreasing temperature. The measurement device is effective to carry out dynamic testing of microstructure from -50°C to room temperature.
What problem does this paper attempt to address?