Thin-Film Thermocouple Array for Time-Resolved Local Temperature Mapping

Haixiao Liu,Weiqiang Sun,Qing Chen,Shengyong Xu
DOI: https://doi.org/10.1109/led.2011.2165522
IF: 4.8157
2011-01-01
IEEE Electron Device Letters
Abstract:This letter reports on a technique to obtain time-resolved 2-D mapping of local temperatures on a solid substrate by employing an array of Cr-Ni thin-film thermocouples (TFTCs). Using 100-nm-thick Cr-Ni TFTCs, a stable and reproducible thermopower of 26.2 +/- 1.5 mu V/K with temperature resolutions better than 0.1 K was obtained. Investigation showed that the thermopower of these thermocouples had no obvious dependence on their junction area down to 3 x 3 mu m(2). In an array of 18 individual thermocouples, a relative standard deviation of 0.31% was measured for the thermopower. This technique may have applications in, e.g., thermal failure analysis, real-time and on-site thermal sensing for integrated circuits, and other modern electronic, optical, and thermal devices.
What problem does this paper attempt to address?