Integrated design and fabricate of high sensitivity built-in thin-film thermocouple temperature measurement tool

Jinguo Chen,Ying Lin,Dongxu Zhao,Siyuan Gao,Minli Zheng,Weiping Ma,Baoliang Chen
DOI: https://doi.org/10.1093/jom/ufae008
IF: 1.455
2024-01-01
Journal of Mechanics
Abstract:Abstract Cutting temperature is playing a key role in evaluating the cutting process, which significantly affects the tool wear and the quality of the workpiece. Aiming at the problems of low precision, low aging, and poor stability of cutting temperature measurement on the front tool face, an integrated design and production scheme of a high sensitivity built-in wireless temperature measurement tool was proposed. The temperature distribution position on the front tool face was analyzed with 3D finite element simulation software, and the thermal contact position of the main and secondary film thermocouples was determined. SiO2 insulated films and NiCr/NiSi film thermocouples were prepared on the front tool surface by femtosecond laser micromachining, electrolyte-plasma polishing, plasma enhanced chemical vapor deposition and magnetron sputtering, and a static calibration experiment system for sensitivity and accuracy of the temperature measuring tool for the film thermocouple was established, and Seebeck coefficient of the film thermocouple was obtained. According to the actual cutting conditions, the wireless temperature measuring system of the thin film thermocouple tool was built and the field cutting test was carried out to obtain the influence law of different cutting parameters on the cutting temperature, and further verify the feasibility of the thin film temperature measuring sensor. The research results show that: Seebeck coefficients of the two kinds of thermocouples prepared by the NiCr/NiSi thin film thermocouple temperature measuring tool are 34.97 μV/°C and 34.96 μV/°C, and the slope of the temperature data fitting curve is 1.00398 and 0.997475, respectively. The linear correlation coefficient R2 is close to 1, which is close to the standard K-type thermocouple, which shows good sensitivity and accuracy. At the same time, the temperature measurement results are close to the commercial standard K thermocouple, and the error is less than 5%, indicating that the developed film thermocouple has a high measurement accuracy and can meet the needs of temperature measurement. Actual cutting test is carried out with developed wireless temperature measuring device of thin film thermocouple, which shows this device can meet the requirements of tool temperature measurement, and the feasibility of thin film temperature measuring sensor is further verified. The research provide technical reference for industrial intelligent manufacturing in order to realize the wireless measurement of cutting area temperature of tool front.
mechanics
What problem does this paper attempt to address?
The paper primarily focuses on addressing the issue of accurately measuring cutting temperature during the cutting process, particularly in the area ahead of the cutting edge. Traditional methods such as natural thermocouples, built-in thermocouples, and non-contact infrared thermography have limitations in practical applications, such as measurement errors, installation space constraints, and difficulty in effectively detecting temperature changes in the cutting zone or adjacent areas. To overcome these shortcomings, the authors propose an integrated design and manufacturing scheme to develop a high-sensitivity built-in thin-film thermocouple temperature measurement tool. This tool can monitor the temperature in real-time during the manufacturing process and has the following features: 1. **Design and Preparation of Thin-Film Thermocouples**: Using femtosecond laser micromachining technology, SiO2 insulating films and NiCr/NiSi thin-film thermocouples were prepared on the rake face of the cutting tool. Electrolytic plasma polishing technology was used to ensure the quality of the groove bottom surface. 2. **Construction of Wireless Temperature Measurement System**: A wireless temperature measurement system was established to measure the temperature data of the thin-film thermocouple tool, and cutting tests were conducted to verify its feasibility. 3. **Performance Verification**: Experiments verified that the prepared thin-film thermocouples have good sensitivity (Seebeck coefficient of approximately 34.97 μV/°C) and accuracy, comparable to commercial standard K-type thermocouples. The linear correlation coefficient of the measurement results is close to 1, with an error of less than 5%. 4. **Practical Application**: Through actual cutting tests with the developed wireless temperature measurement device, it was demonstrated that the device can meet the needs of tool surface temperature measurement, further verifying the feasibility of the thin-film temperature sensor. In summary, this study aims to solve the problems of traditional methods in cutting temperature measurement by developing a novel high-sensitivity built-in thin-film thermocouple temperature measurement tool. It provides technical support for the wireless measurement of cutting zone temperature in industrial intelligent manufacturing.