A charge pump based timing-skew calibration for time-interleaved ADC

Peng Zhang,Zhijie Chen,Hegong Wei,Saiweng Sin,U. Seng-Pan,Zhihua Wang,Rui Paulo Martins
DOI: https://doi.org/10.1109/MWSCAS.2011.6026341
2011-01-01
Circuits and Systems
Abstract:This paper presents a background-calibration technique of timing skew for time-interleaved analog-to-digital converters (TIADCs). Without any kind of additional calibration signals, the timing skew between any two adjacent interleaved channels is detected by the capacitive charge pumps, and minimized by the digitally controlled delay elements (DCDEs). The calibration behaviors are analyzed and verified on transistor-level simulations. An 8-bit 4-channel TIADC is used as an example for demonstration. The simulation results show that the proposed technique can improve the SNDR from 35.1 dB to 49.6 dB at Nyquist input frequency as the extreme case.