Characteristic Research and Experiment of Micro Accelerometer Startup Drift

DAI Gang,LI Mei,DU Lianming,HE Xiaoping,SU Wei,SHAO Beibei
DOI: https://doi.org/10.3969/j.issn.1004-1699.2011.10.009
2011-01-01
Abstract:The bulk silicon micro accelerometer exists the problem of long start-up time and large start-up drift which can not satisfy the requirement of fast start-up application.In order to reduce the start-up time of the micro accelerometer,this paper researches on the start-up characteristic of the micro accelerometer,analyzes the heat generating and its conduct in the micro structure and the detection circuit and establishes the finite element model for the thermal analysis.A thermal resistor with the micro structure inside the chip package was fabricated to verify the analysis.Finally,with a series of experiment,it was proved that the thermal conduction and time drift are the main reason of the micro accelerometer startup drift.