A NOVEL MODEL FOR PREDICTING FLOW ACCELERATED CORROSION RATE IN REDUCER

陆晓峰,朱晓磊,凌祥
2011-01-01
Abstract:A new prediction model was proposed to calculate the flow accelerated corrosion (FAC) rate in reducer, which was coupled the steady-state mass transfer model electrochemical theory and one-dimensional galvanic corrosion model. Firstly, the steady-state mass transfer model was used to obtain the distribution of concentration polarization current density and the concentration polarization corrosion potential of velocity extreme point near the wall of reducer. The galvanic corrosion current density was calculated by substituting the potential into one-dimensional galvanic corrosion model. The new model was employed to calculate the reducer; the results showed that the corrosion current density of large-end was larger two orders than that of small-end. Compared with the FAC rate calculated by the wall shear stress theory, presented by Efird and Cheng, or by purely steady-state mass transfer theory, the results obtained by the new model have good agreement with the practical situation which were counted 2000 pipe fittings in Taiwan nuclear power plant by Kuen Ting. The statistical result showed that the large-end of reducer appeared the maximum of reduction of thickness.
What problem does this paper attempt to address?