Experimental Study of Measurement Method for Insulating Structure-borne Sound
Liu Yansen,Sheng Meiping,Wang Minqing,Zhang Junfeng,Fan Yuling
DOI: https://doi.org/10.3321/j.issn:1003-8728.2007.11.007
2007-01-01
Abstract:Structure-borne sound insulation measurement is widely applied to acoustic structural design,environment noise control,architectural acoustics,and national defence industry,etc.Using the time domain separation technology through edge diffraction and virtual instrument test technology,we do the experimental study of how the free-field method is applied to structure-borne sound insulation measurement.In the experimental study,we use aluminum panel as test place.On this basis,we conduct the theoretical analysis of the influence of edge diffraction,pulse width of test signal,system gain,and average time,on the measurement results.Furthermore,we propose the sample equivalent enlargement technique and combinatory broadband transmission technique so as to improve signal to noise ratio measurement and frequency response bandwidth properties.The results show that within the effective bandwidth,sound insulation measurement results agree well with the theoretical value,the average difference being only 0.05dB.The free-field method measures structure-borne sound insulation without requiring a special-purpose sound insulation chamber.Its measurement results are precise and reliable,especially suitable for field engineering test.