Recovery of Holdoff Voltage and Gas Density in Short Nitrogen Gaps

蔡新景,邹晓兵,王新新
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.06.036
2011-01-01
Abstract:In order to find methods to enhance the repetitive operation frequency of gas spark gap switches,the gaseous recovery in short nitrogen spark gaps was investigated with "two-pulse method",Mach-Zehnder interferometer,and photography.The results reveal that there always exists a plateau between two rising edges on the curve of the voltage recovery obtained with "two-pulse method",and this plateau divides the process of the voltage recovery into two phases: the recovery of the static breakdown voltage and the recovery of the overvoltage withstand ability.The later phase takes a much longer time than that the former.By comparing the voltage recovery and the recovery of the gas density that is determined with Mach-Zehnder interferometer,it is found that the gap only recovers its static breakdown voltage even when the gas density of the gap fully recovers.The reason for the delayed recovery of the overvoltage withstand ability may be the residual nitrogen atoms from the previous discharge.These nitrogen atoms are known for their ability to store energy over extended periods of time and may recombine the cathode to produce the initial electrons for the succeeding discharge.The discharge photographs taken in the experiments with "two-pulse method" show that the second breakdown does not necessarily follow the path of the first breakdown,which means that the weakest point in electric insulation may locate at any point in the expanded volume centered around the extinguished spark channel.