Time-frequency Analysis on Torsional Vibration of Turbo-generator Shafts

向玲,杨世锡,唐贵基,甘春标
2011-01-01
Abstract:Based on dynamic simulation system of power grid and torsional vibration simulator of turbo-generator shaft,an experimental test was conducted to study the torsional vibration under typical and disturbed working conditions,after which the non-stationary vibration signals were analyzed using Hilbert-Huang Transform(HHT) method.Results show that under short-circuit fault,when torsional vibration of the electrical-mechanical interaction kind exists,the amplitude of torsional vibration increases greatly while the stimulated frequency changes;the 3D time-frequency graph indicates that the amplitude first rises and then drops,forming a corresponding peak-to-valley curve of bottleneck like.The holding time of torsional vibration caused by electrical-mechanical interaction in the case of 3-phase short-circuit fault is longer than that of 2-phase short-circuit fault.Hilbert spectrum quantitatively describes the rapid process of vibration frequency and amplitude varying with the time under electrical disturbances.
What problem does this paper attempt to address?