High precision and high frequency pulse laser ranging system

Rongyi Ji,Changming Zhao,RenXuecheng
DOI: https://doi.org/10.3969/j.issn.1007-2276.2011.08.014
2011-01-01
Abstract:In three-dimensional (3D) laser scanning detection system, the measurement repetition rate and measurement precision of laser ranging are the key parameters affecting the performance of the whole system. The work characteristics of 3D laser scanning detection system were introduced, and a high repetition rate and high measurement precision pulse laser ranging system based on the Nios II soft-core was designed. According to the analysis of the factors which affected the repetition rate and precision of range measure, the double-threshold time discriminator was adopted to produce timing mark for the start-stop time discrimination, and the TDC-GP2 high-precision interval measuring chip was used to achieve high precision on time measure. In addition, the time measure control system based on the Nios II soft-core was designed to improve the measurement repetition rate. Experimental results show that the measurement repetition rate of 20000/s and the ranging precision of ±3 cm are achieved. Compared with the traditional MCU time measure control system, the designed system owns the advantages of high repetition rate and high measurement precision, furthermore, it is more expandable and flexible.
What problem does this paper attempt to address?