High-precision Pulsed Laser Measuring Distance by Time Delay Method

SHI Zhi-yong,PAN Xiao-sheng,ZHANG Qian
DOI: https://doi.org/10.3788/ope.20142202.0252
2014-01-01
Optics and Precision Engineering
Abstract:Since the accuracy of laser ranging depends on the accuracy of time measurement,this paper introduces a method to improve the accuracy of time measurement.Under the control of a Field Programming Gate Array(FPGA),the electric signal is transported into the CLK port of a D flip-flop through a delay circuit,the laser sends a laser beam to the target and the target reflects the laser beam back to the photoelectric converter.Then,the laser beam is changed to an electric signal and transported to the D port of D flip-flop.By adjusting the delay time of electric signal produced by a delay chip and mechanical displacement,the laser makes the signal of input ports of D flip-flop arrive at the target at the same time.Therefore,the delay time can be utilized to determine the time of laser arriving the target.Furthermore,the FPGA is used to count the pulse of a constant temperature crystal oscillator with 100MHz,the MC100EP195is used to delay and then the accuracy of time measurement is improved to 0.3ps by the mechanical location method.The experimental results show that themeasurement accuracy of the target in 1km has reached to 0.1mm,which means that the method can satisfy the requirements of high-precision ranging.