Feature Analysis and Simulation Method of Thermo-Coupled Air Separation Unit with Load Change Operation

ZHU Lingyu,ZHOU Lifang,QIAN Jixin
DOI: https://doi.org/10.3969/j.issn.0438-1157.2011.08.025
2011-01-01
Abstract:Load change problem synchronized with pipe network pressure increasing of three thermo-coupled columns in a cryogenic air separation unit was discussed.Due to the thermo-coupled features among the distillation columns,the simulation of the load change operation of a cryogenic air separation unit is difficult.Analytical results reveal that slight change of the operation variable can cause dramatic change of some other variables,which results in the difficulties of convergence due to inaccurate gradient approximation.The homotopy-based backtracking method(HBM)can efficiently deal with the load change simulation of the thermo-coupled system.The nitrogen block phenomena can also be simulated with this method.
What problem does this paper attempt to address?