STRUCTURAL DESIGN AND ANALYSIS FOR A DOUBLE-BAND COLD MASS SUPPORT OF MICE COUPLING MAGNET

H. Wu,X. K. Liu,L. Wang,S. Y. Li,X. L. Guo,H. Pan,F. Y. Xu,M. A. Green
DOI: https://doi.org/10.1063/1.3422471
2010-01-01
AIP Conference Proceedings
Abstract:The cooling channel of Muon Ionization Cooling Experiment (MICE) consists of eighteen superconducting solenoid coils, which are magnetically hooked together. A pair of coupling magnets operating at 4 K is applied to produce up to 2.6 T magnetic field on the magnet centerline to keep muon beam within the RF cavity windows. The peak magnetic force on the coupling magnet from other magnets in the MICE channel is up to 500 kN in longitudinal direction, and the requirements for magnet center and axis azimuthal angle at 4 K. are stringent. A self-centered double-band cold mass support system with intermediate thermal interruption is applied for the coupling magnet. The physical center of the magnet does not change as it is cooled down from 300 K to 4.2 K with this support system. In this paper the design parameters of the support system are discussed. The integral analysis of the support system using FEA method was carried out to determine the tension forces in bands when various loads are applied. The magnet centre displacement and concentricity deviation form the axis of the warm bore are obtained, and the peak tension in support bands is also determined according to the simulation results.