Experimental study on critical breakage stress of float glass with different thicknesses under conditions with temperatures of 25 and 200°C
Qiyuan Xie,Heping Zhang,Dong Y. Si
DOI: https://doi.org/10.1002/fam.1052
2011-01-01
Fire and Materials
Abstract:objective of this study is to directly measure the critical breakage stress for glass through mechanical tensile experiments based on MTS 810 apparatus. Two series of experiments were, respectively, conducted under the condition with a room temperature (25 degrees C) and a hot environment (200 degrees C) for float glass. The results show that the critical breakage stresses of 6, 8, 10 and 12mm float glass are, respectively, 74, 127, 158 and 198% larger than that of 4mm float glass under the condition with a room temperature (25 degrees C). Similarly, the critical breakage stresses of 6, 10 and 12mm float glass are, respectively, 29, 72 and 93% larger than 4mm glass in the hot environment (200 degrees C). In addition, through the comparison between the two series of experiments, it suggests that the critical breakage stresses of 6, 8, 10 and 12mm thick float glass in a hot environment are, respectively, 7, 48, 16 and 19% smaller than that in a room temperature. It is suggested that the measured critical breakage stress of float glass here is relatively smaller than those in the previous measurements. Copyright (C) 2010 John Wiley & Sons, Ltd.