Determination of Critical Breakage Conditions for Double Glazing in Fire

Yu Wang,Ke Li,Yanfei Su,Wei Lu,Qingsong Wang,Jinhua Sun,Linghui He,K. M. Liew
DOI: https://doi.org/10.1016/j.applthermaleng.2016.09.079
IF: 6.4
2017-01-01
Applied Thermal Engineering
Abstract:Double glazing unit normally demonstrates better fire resistance than single glazing, but the knowledge on its thermal behavior and heat transfer mechanism during fire is limited. In this work, nine double glazing units were heated by a 500 x 500 mm(2) pool fire. The incident heat flux, temperature on four surfaces, breakage time and cracking behavior were obtained. The critical breakage conditions for interior and exterior panes were determined through gradually decreasing the glass-burner distance from 750 mm to 450 mm. It is established that in double glazing the pane at ambient side can withstand significantly more time than the pane exposed to fire. The critical temperature difference for interior pane is 60 degrees C; the critical temperature of exterior pane breakage is much higher due to no frame-covered area. In addition, the heat flux at the time of crack initiation is 6 kW/m(2) for the pane at fire side, while more than 25 kW/m(2) for ambient side pane. To reveal the heat transfer mechanism in glazing-air-glazing, theoretical and numerical investigations are also performed, which agrees well with the experimental results. (C) 2016 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?