The Effect of Glass Panel Dimension on the Fire Response of Glass Façades

Yu Wang,Yi Zhang,Qingsong Wang,Yi Yang,Jinhua Sun
DOI: https://doi.org/10.1016/j.conbuildmat.2018.06.088
IF: 7.4
2018-01-01
Construction and Building Materials
Abstract:Different sizes and shapes of glass products are increasingly employed in building envelopes, but little is known about the effect of glass panel dimension on the fire safety of glass facades. In the present work, two experiments with glass dimensions of 300 x 300 x 6 mm(3) and 600 x 600 x 6 mm(3) were conducted to verify a finite element method model in the authors' in-house software. Then, a total of 27 numerical cases were designed. The glass panel with dimensions from 100 x 100 mm(2) to 1000 x 1000 mm(2) and length-to-width aspect ratios of 400:1, 100:1, 25:1, 25:4, 4:1 and 25:16 were studied. The breakage time, stress distribution and crack path were calculated and demonstrated. It was established that the fire resistance of glass decreases with the panel dimension increase regardless of the mesh size and number. While the glass panel with a larger aspect ratio presents better fire resistance. The stress distribution variance caused by size and shape effect is responsible for the different fire performances of glass facades, but the number and distribution of small flaws and defects in glazing are also important. The results are intended to provide references for fire safety optimization of glass facades. (C) 2018 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?