Current-Voltage Characteristics of the Hybrid Particulate Collector

LONG Zheng-wei,SONG Qiang,LI Shui-qing,YAO Qiang
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.14.005
2010-01-01
Abstract:A bench-scale hybrid particulate collector(HPC) was constructed and its current-voltage characteristics were studied experimentally with seven types of perforated-plate and two types of bag.The current-voltage characteristics of HPC with the steel bag were also studied for comparison.The measured results were compared with the predictions of three different theories for the conventional electrostatic precipitator.A finite volume numerical method on unstructured grid was used to calculate the current-voltage characteristics with different distances between the perforated plate and the bag plate.The perforated-plates had considered the diameter,the array and the shape of the hole.The bag materials had considered the polyphenylene sulphide(PPS)filter and the antistatic polyethylene terephthalate(PET)filter.Results indicate that the geometrical parameters and the bag material have little influences on the current-voltage characteristics.But the currents decrease a lot when the hole's open ration is higher than 0.5.The current-voltage characteristics of the HPC with steel bag change little compared to that of the HPC with PPS or PET bag.It proves that the PPS and the PET filter have same electric conduction with steel in the HPC.Among three theories,the mean of the predictions of Bhm's and G.Cooperman's expression agree well with the measurements.The numerical results show that the distance between the perforated plate and the bag has big influence on the bag plate current.
What problem does this paper attempt to address?