Simulation and Experiments for Optimization of Circular Peristaltic Micropumps

DU Min,YE Xiong-ying,WU Kang,CHEN Feng,ZHOU Zhao-ying
DOI: https://doi.org/10.3969/j.issn.1672-6030.2010.04.008
2010-01-01
Abstract:Leakage of the peristaltic micropumps with typical rectangular cross section and its influence on pump performance were analyzed,which identifies that reduction of the leakage can enhance the pumping pressure and self-pumping ability of the micropump.The influence of parameters on leakage ratio of the micropump was simulated based on the 2D contact model established with Ansys finite element analysis method and it was concluded that the aspect ratio and pressing force were the main parameters that had impact on the leakage ratio.Within a certain range,a smaller aspect ratio and a larger pressing force led to better sealing.A fitted equation for leakage ratio calculation was obtained using simulation results.According to the calculation results,micropumps with various aspect ratios and pressing forces were designed and fabricated,whose flow and pumping pressure were tested,and the smallest leakage ratio of 2% was achieved in the experiment.Experimental results indicate that the leakage ratio calculated with the simulation-based fitted equation is in good agreement with that measured in the experiments.Optimization of the structural parameters of the micropumps on basis of the fitted equation can effectively decrease the leakage ratio,improve the accuracy of the flow control and enhance the pumping pressure and self-pumping ability.
What problem does this paper attempt to address?