Fatigue Tests of Single Layer and Laminated Glass Plates with Point Supports

SHI Yongjiu,HE Xiaoping,WANG Yuanqing,Ken Y LUO,SHU Ganping,SHI Gang
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2010.03.023
2010-01-01
Abstract:Brittle fatigue failure,which easily occurs in glass plates with wind loads,must be well understood for glass curtain wall designs.This paper describes high frequency fatigue tests on single layer and laminated glass panels.The fatigue stress amplitudes were determined according to the current codes as well as in static loading tests.The maximum stress at the center of the glass panel was used to quantify the applied fatigue load by a loading test.The test results show no fatigue after 2 million-cycle loading.The remaining static strength after the fatigue tests showed no strength reduction after the 2 million cycle loadings.The experiments show that point-supported single layer and laminated glass panels both have adequate fatigue capacity.