Finite Element Analysis to Point-Supported Insulating Glass Unit Bearing Properties

Ying Ma,Yongjiu Shi,Yuanqing Wang
DOI: https://doi.org/10.3969/j.issn.1000-4939.2006.01.025
2006-01-01
Abstract:When an insulating glass unit is subjected to a uniform lateral pressure, a complex interaction occurs among the leeward, windward plates and the air trapped inside the unit. The existing code and specification distribute the loads between the two plates according to their bending stiffnesses. Finite element method is adopted to analyze the structural behaviors of the insulating unit, and an iterative procedure is developed to permit accurate analysis of load sharing between the leeward and windward plates. The following conclusions are achieved that the load sharing result is affected significantly by the aspect ratio, insulating layer thickness, etc., and the windward plate may carry most of the lateral loads under certain conditions. It is suggested that the design criterion method for load sharing in existing Chinese code should be modified, and the temperature variations should be taken into account in design process.
What problem does this paper attempt to address?