Enhancing the life of direct methanol fuel cell

Xiaofeng Xie,Min Liu,JinHai Wang,Shubo Wang,Tao Zhou,Virendra K. Mathur
2010-01-01
Abstract:Cyclic voltammetry (CV) was performed to oxidize CO, absorbed on catalysts for mitigating performance losses. The cathode and the anode were scanned separately for the removal of CO from the catalysts. The performance of direct methanol fuel cell (DMFC) dropped after 140 hr lifetime test; but CV restored performance loss greatly by removing CO on catalysts. The effect of CO poisoning was more damaging on the cathode than on the anode, which was mainly attributed to the CO produced by methanol crossover. The intermediate product CO was firmly absorbed and accumulated on the Pt catalysts, occupying the active sites then reducing the reaction rate, causing significant degradation of DMFC. This is an abstract of a paper presented at the 2010 Spring National Meeting (San Antonio, TX 3/21-25/2010).