Experimental Study on Load Capacity of Reinforced Concrete Columns with Partial Length Corrosion

WANG Xiao-hui,LIANG Fa-yun,LIU Xi-la
DOI: https://doi.org/10.3321/j.issn:1006-2467.2009.06.033
2009-01-01
Abstract:Accelerated corrosion technique was performed on the tensile or compressive longitudinal steel of the reinforced concrete(RC) columns,where only a partial length of the longitudinal steel was corroded.Experimental study was carried out on the RC columns with different partial length corrosion in tensile or compressive zone.It is showed that the load capacity of the corroded RC column decreases with the increase of the corrosion level.The failure of the corroded column occurs in the partial length,mainly developed from or located nearby the corrosion cracks.For RC column with large eccentricity,load capacity of the column is influenced by the high corrosion level in tensile zone.For RC column with small eccentricity,load capacity of the column greatly decreases due to the highly corrosion level in compressive zone.The main cause of the great reduction of the load capacity of the RC column with partial length corrosion lies in the destruction of the longitudinally mechanical integrality of the column in the partial length.
What problem does this paper attempt to address?