The ignition delay measurement of atomized kerosene air mixture in an aerosol shock tube

Qin LIAO,Sheng-li XU
DOI: https://doi.org/10.3969/j.issn.1672-9897.2009.03.015
2009-01-01
Abstract:A new aerosol shock tube was developed for measuring ignition delay time τig of kerosene air mixture and imaging of flame. Aerosol was formed in a tank by an atomizer. Neither condensation, nor adsorption of droplet was found obviously in the test section. The condition of tailored contact surface was run to provide test time more than 10ms and it is enough for τig measurement at low temperature of 1000K. PCB gauges were used to detect pressure and photomultiplier PMT to record OH emission. ICCD was used to record Mie scattering of droplets and flame emission. The results indicated that a rather homogeneous aerosol can be obtained by this new shock tube, atomizer and filling system. The averaged SDM is ranged from 2 to 5 μm. In the case of stochiometric mixture, τig is ranged from 70 μs to 6ms at pressure 0.1 MPa and temperature from 1300 K to 1700 K. The ln(τig) almost depends on 10000/Tig linearly. In contrast to gasified kerosene, τig is approximately the same at high temperature but large at low temperature. This does mean aerosol is actually in two-phase at low temperature.
What problem does this paper attempt to address?