Signal Quality of Dual-tip Electrical Conductivity Probe for Measurement of Bubble Parameters

韩梅,沙作良,伍倩,张念,王铁峰,王金福
DOI: https://doi.org/10.3321/j.issn:1009-606x.2009.02.003
2009-01-01
Abstract:A dual-tip conductivity probe for measurement of bubble parameters in a gas-liquid flow was studied.The effects of the probe structure,measurement circuit and sampling method on the bubble signal quality measured with the probe were investigated,and the measures to improve the signal quality were proposed.The experimental results show that the signal response is faster when the conductive length of probe tips is smaller.This effect becomes insignificant when conductive length is smaller than 0.025 mm.The probe tip should be connected to the cathode of measurement circuit to avoid the electrical oxidation corrosion that caused damage of the probe tip.The better bubble signal response is obtained by using optimum electrical resistance in the measurement circuit with smaller electrical resistance of the probe tip.The improved signals with large difference of 3 V,fast response and little noise are obtained with the optimal conditions.
What problem does this paper attempt to address?