Experimental Research on the Breakdown Mechanism of Magnet Wires Used in the Inverter-fed Motors

ZHOU Li-ren,WU Guang-ning,LUO Yang,CAO Kai-jiang
DOI: https://doi.org/10.3321/j.issn:0258-8013.2009.30.017
2009-01-01
Abstract:The failure of magnet wires used in inter-turn insulation of inverter-fed motor winding is the main cause which leads to the motor insulation breakdown. This paper conducted experiment, including electrical breakdown, thermal breakdown and electrical tree breakdown, on magnet wires used in the insulation of JD117 inverter-fed motor and meanwhile combining with scanning electrical microscope (SEM) and energy spectrum analysis, the corresponding breakdown mechanisms were analyzed. The experiment results reveal that all the breakdown main bodies are located at the pointedness and insulation joint of magnet wires. During the process of electrical breakdown, the carbonization degree is very large and drastic chemical reaction takes place. During the process of thermal breakdown, the temperature of peripheral area of breakdown main body is very high and the carbonization degree is serious and however carbonization degree of inner part of breakdown main body is relatively smaller. The reaction is smaller compared with the electrical breakdown. The electrical tree breakdown time is quite long and the life span of magnet wire is 11 h. It is found that the aluminum occupies the highest content tested by energy spectrum analysis.