Research on Electrical Pulse Endurance Test System of Magnet Wire Insulation for Inverter-Fed Motors

TU De-min,WANG Xia
DOI: https://doi.org/10.3969/j.issn.1009-9239.2005.02.011
2005-01-01
Abstract:The parameters of electrical pulse voltage in a simulative generator are determined on the basis of pulse width modulation(PWM)of voltage wave in inverter-fed motor.The work principle of test system developed for endurance of electrical pulse strength of electrical insulaˉtion is presented.It is shown by the measurement results that the main properties of our test system reach to those of advanced product abroad.Moreover,the test system satisfies the deˉmand of quality evaluation of magnet wire insulation used in inverter-fed motor at home.