Measurement of Lidar's Co-Boresight Alignment Margin

狄慧鸽,王建宇,舒嵘
DOI: https://doi.org/10.3969/j.issn.1007-2276.2009.01.029
2009-01-01
Infrared and Laser Engineering
Abstract:The co-boresight alignment margin is an important parameter affecting lidar's performance. The way of measuring lidar's co-boresight alignment margin was presented. For system with inner short-range protecting circuit, a new method was brought forward. The measurement system included an echo-simulator and an adjustor. The echo-simulator was used to bring sequenced echoes which were lagged related to the lidar's main pulse. After the lidar laser and echo-simulator laser were co-boresighted by the adjustor, the lidar receiver was scanned by the echoes and the output was noted. According to the system output and the echo direction, the co-boresight alignment could be obtained. A measurement system was given, which could produce the simulated echo with beam divergence of 0.7mrad. The lidar was measured and the reliability was also validated. The system error is analyzed and the result is less than 45μrad.