Investigation of Load Impact on Output Capability of Impulse Voltage Generators

王浩洋,孙伟,傅正财,陈坚
2009-01-01
Abstract:The entrance capacitances of GIS and HV cable can reach 3 000 pF to 10 000 pF in impulse voltage test.It is necessary to improve the output capability of the impulse voltage generators(IVG) which were designed without consideration of large capacitance loads.In this paper,by applying the ATP simulation method,a 15-stage 3 000 kV IVG with a high-voltage RC-filter at the output terminal for improving output capability is analyzed.The waveform influencing factors including load,total inductance,and equivalent resistance,and the output efficiency are investigated.It is shown that the above improving method can enhance the IVG output capability from 4 000 pF to 11 000 pF,with the waveform overshoot being controlled within 10%.In addition,the length limit of HV connecting wire is suggested.
What problem does this paper attempt to address?