Electrospinned PCL nanofiber and its diameter measurement correction

Liang SUN,Jun WANG,Ping-chou HAN
DOI: https://doi.org/10.13229/j.cnki.jdxbgxb2008.06.003
2008-01-01
Abstract:Measurements of the electrospinned polymer nanofibers showed that the fibers are not quite circular in section shape, they tend to be slightly flattened out at the top due to the effects of gravity and the surface viscosity between nanofiler and substrate, especially for the soft polymer nanofihers. Defining the diameter measured by AFM as vertical diameter, and that by SEM as horizontal diameter, the effects of two main parameters, applied electric voltage and polymer solution concentration, on the average diameter of the electrospinned PCL nanofiber were studied. The quantitative relations between the horizontal and vertical diameters of the nanofibers electropinned by the PCL solution with the concentration of 10% were obtained, and the empirical formulas were derived. The results showed that the horizotal diameter of this fiber is about 1.5 times as the vertical diameter.