Influence of Prying Force on Tension Carrying Capacity of Bolted Connections

吴兆旗,张素梅
DOI: https://doi.org/10.13197/j.eeev.2008.06.022
2008-01-01
Abstract:Prying force often appears in the tensile bolted connections.It will decrease the carrying capacity and the fatigue behavior of the connections.So,it is necessary to take the prying force into account in the connection design.However,there are no specifications on the estimate of prying force in the current code for design of steel structures(GB50017).In this paper,the T-stub connections were analyzed by finite element method.The influence of geometric and physical parameters on the prying force was discussed through the investigation of 40 specimens with different dimension and material properties.The finite element analysis results were compared with those by the commonly used method.The comparison shows that AISC-LRFD ignores the increase of the flange bending moment capacity in the bolt line by the clamp effect of bolt heads.So it underestimates the prying force in the connections with the flexible flange.AISC-LRFD with modification of the bending moment capacity limit of the flange at the bolt line can predict the prying force accurately.
What problem does this paper attempt to address?