Optimization of multi-pass distillation tray column by CFD method

XueYing Gao,Chunjiang Liu,Xigang Yuan,Guocong Yu
2008-01-01
Abstract:Simulation of the flow and mass transfer performance in a four-pass distillation tray column and optimized configuration of the tray was carried out using CFD method. The existence of liquid circulation area was apparent on side-tray rather than middle-tray, which was in agreement with literature. Velocity and concentration profile showed that the maldistribution on side-tray was more obvious than the middle-tray. The tray efficiency was the highest at the liquid load ratio of 0.5 between side-tray and middle-tray. When the structure of downcomer was modified into a specified configuration, simulation result showed that liquid circulation area became smaller and velocity and concentration distribution on side-tray become relatively uniform. In this case, mass transfer was intensified and tray efficiency was increased by 6.4%. This is an abstract of a paper presented at the AiChE Spring National Meeting & 5th Global Congress on Process Safety (Tampa, FL 4/26-30/2009).
What problem does this paper attempt to address?