Control Strategy of Paralleled UPS System

于玮,徐德鸿,周朝阳
2008-01-01
Abstract:A load-sharing control scheme is studied for the paralleled uninterrupted power supplies (UPS's). Integrated with the active and reactive power control and the output filter current control, the proposed load-sharing control can improve the current-sharing quality and stability of the paralleled UPS system. In order to improve the reliability of the whole system, active and reactive power and filter current signals are transmitted through CAN bus. In the experiments, two paralleled 30 kVA three-phase UPS's are used.