Degradation Behavior of Stator Insulation for Large Generators Using X-Ray Diffraction Method

Yanpeng Hao,Hengkun Xie
DOI: https://doi.org/10.3321/j.issn:1000-6753.2007.09.004
2007-01-01
Abstract:Insulation condition diagnosis technology is based on the investigation of insulation degradation behavior or aging mechanism. The degradation behavior of mica in stator insulation under operating stresses is investigated by X-ray diffraction (XRD) method in this paper. The insulation specimens were cut from a standby and an aged stator bar operating for 23 years in a 300 MW/18 kV generator. Complicate changes are found through chemical formula analysis of mica crystal based on XRD patterns of insulation specimens. The atom count of K in mica crystal decreases obviously from 1 for the unaged to 0.75 for the aged. This degradation behavior may be an aging progress, in which the edge of mica crystal is corrupted under some acids produced by partial discharges in insulation, and potassium ion is separated from the edge of mica leading to the degradation of epoxy-mica insulation. In addition, the aluminum ion in mica crystal of aged insulation is replaced with ferrum and lithium ions, and the hydroxyl is with fluorine. However, it is difficult to describe the chemical progress during the replacement courses.
What problem does this paper attempt to address?